logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
IP Testing Equipment
Created with Pixso.

IEC 60529 IPX5 IPX6 Water Jet Hose Nozzle Test Equipment 6.3mm 12.5mm Ingress Protection Tester

IEC 60529 IPX5 IPX6 Water Jet Hose Nozzle Test Equipment 6.3mm 12.5mm Ingress Protection Tester

Brand Name: HongCe
Model Number: HH0804T
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T,L/C
Supply Ability: 100 sets per month
Detail Information
Place of Origin:
Guangzhou, Guangdong, China
Certification:
Third-party certification certificate(cost additional)
Nozzle Bore:
Ø6.3 Mm IPX5, Ø12.5 Mm IPX6
Flow Rate:
12.5 L/min IPX5, 100 L/min IPX6
Flow Tolerance:
±5%
Jet Distance:
2.5-3.0 M
Pump Power:
3 KW
Power Supply:
AC 220V Single Phase Or AC 380V Three Phase, 4 KW
Water Tank:
500 L
Frame Material:
304 Stainless Steel
Packaging Details:
Toolbox or plywood
Highlight:

IPX5 IPX6 Jet Nozzle Rig

,

Closed Loop Jet Flow Control

,

Enclosure Hose Proof Verification

Product Description

The hose test is the clause that surprises people. IPX4 passes, the sample looks dry, and then the IPX5 jet at a 12.5 mm nozzle distance finds the one cable gland that was never tightened. This water jet hose nozzle test equipment lets you run clauses 14.2.5 and 14.2.6 exactly as written, with the specified nozzle bore, the specified flow, and the specified distance held by a mechanical positioning arm instead of a technician's arm.

Our customers buy this rig for one of two reasons: they are preparing an enclosure for a notified body report and want to arrive with data, or they are a test house that has to produce the same jet every day for different samples. The design answers both cases, because the nozzle station, flow loop, and sample turntable are independent of the operator's skill.

Typical Applications
  • EV charging stations, wall boxes, and charging gun assemblies
  • Outdoor luminaires, stage lighting, washdown fixtures, and industrial flood lights
  • Energy storage cabinets, combiner boxes, PV junction boxes, and inverters
  • Marine, agricultural, and food processing equipment housings that face hose-down cleaning
  • Traffic control boxes, pole-mounted cameras, and roadside sensor housings
  • Testing laboratories and third-party certification bodies running IEC 60529 or GB/T 4208
Test Items That Can Be Verified
  • IPX5 jet test — 6.3 mm nozzle, flow 12.5 L/min ±5%, distance 2.5 to 3 m
  • IPX6 strong jet test — 12.5 mm nozzle, flow 100 L/min ±5%, distance 2.5 to 3 m
  • Water ingress behind gaskets, through cable entries, ventilation slots, and door seams
  • Behaviour of drainage weep holes under a continuous strong jet
  • Seal integrity of connectors, plugs, and terminal covers after repeated cleaning cycles
  • Comparative testing of two enclosure designs before tooling release
Technical Parameters
Standards IEC 60529:1989+AMD1:1999+AMD2:2013 clause 14.2.5 and 14.2.6, GB/T 4208
Nozzle bore Φ6.3 mm for IPX5, Φ12.5 mm for IPX6, both supplied as standard
Flow rate 12.5 L/min ±5% (IPX5), 100 L/min ±5% (IPX6)
Jet distance 2.5 to 3.0 m, set by a graduated positioning arm
Test duration At least 3 minutes per square metre, 1 minute minimum, programmable
Flow control Electromagnetic flow meter plus proportional valve, closed loop
Pump Stainless steel multistage centrifugal pump, 3 kW
Controller PLC with 7 inch touch screen, separate IPX5 and IPX6 recipes
Water reservoir 500 L stainless tank with filter and level switch
Frame 304 stainless steel, mobile on castors with levelling feet
Power supply AC 220 V 50/60 Hz single phase or AC 380 V three phase, 4 kW (110 V available)
Footprint Approx. 3200 x 1600 x 1800 mm, weight 450 kg
Core Technology and How Repeatability Is Protected

A jet test is easy to build and hard to make repeatable. Three design decisions do most of the work here.

  • Nozzle bore is measured, not assumed. Every nozzle is supplied with a bore measurement record, and the PLC recipe is locked to the nozzle in use. If someone fits the 6.3 mm nozzle while the IPX6 recipe is active, the machine refuses to start.
  • Pressure-compensated flow. The multistage pump plus proportional valve keeps 12.5 or 100 L/min at the nozzle regardless of filter loading. Without compensation, a partially blocked inlet strainer can cut the jet by 20% and nobody notices until the report is challenged.
  • Distance is a mechanical dimension. The nozzle trolley slides on a rail with a scale and a locking clamp, so the 2.5 to 3.0 m standoff is reproducible between operators. No handheld hoses, no arguments about angle.

The turntable can be rotated manually through the recommended positions or driven continuously, and the sample can be energised during the test through a sealed cable pass-through, so you can watch for a lamp flicker or a fault trip while the jet is running.

HongCe Versus Typical Alternatives
Comparison item HongCe jet rig Entry-level jet benches European lab brands
Flow stability under load Closed loop, compensated for filter loading Fixed pump, flow falls during the run Closed loop, comparable
Nozzle interlock Recipe locked to nozzle, mismatch refuses start None Usually present
Jet distance control Rail with scale and clamp Handheld hose, distance varies Rail, comparable
Nozzle supply 6.3 and 12.5 mm both standard, spares in stock One size, spare on request Both, long lead time
Service Remote diagnosis within one working day Email only Regional agent ticket queue
Budget level Middle of the range, roughly half of European list Lowest Highest
Quality Assurance and After-Sales
  • ISO 9001:2015 production; every unit water run for 4 hours before packing
  • Factory calibration report plus nozzle bore record; third-party calibration available at cost
  • 24-month warranty on PLC and pump, 12 months on valves and seals
  • Nozzles, seals, filter cartridges, and flow meters held in stock for at least 8 years
  • English remote support within one working day; video commissioning included
  • Optional on-site installation and operator training through our service partners
Frequently Asked Questions
Q: Can the same unit run both IPX5 and IPX6?

Yes. Both nozzles are standard, and the recipe sets flow, nozzle, and duration. Only the nozzle swap is physical, and the machine checks it.

Q: Do I need a 500 L tank, or can I connect to mains water?

Both are possible. Mains feed needs at least 0.15 MPa and 120 L/min available at the inlet. Most labs choose the tank because it buffers the flow and lets the water be filtered and reused.

Q: How do I keep 100 L/min without flooding the floor?

The turntable sits over a collection tray that returns water to the tank through a screened drain. A 50 mm drain outlet is provided for overflow, and we recommend a floor channel in the installation drawing we send before delivery.

Q: Is the 3 m distance measured from the nozzle to the sample surface?

Yes, the standard requires 2.5 to 3.0 m from the nozzle to the surface of the enclosure. The rail scale reads that distance directly, and the positioning arm sets the jet angle.

Q: How long is delivery?

20 to 25 days for the standard configuration. Three-phase and 110 V versions may add 5 days.

Q: Can you supply a combined IPX3 IPX4 IPX5 IPX6 station?

Yes. Many customers pair this jet rig with an oscillating tube machine on a shared frame or place them side by side. We can quote a combined water test area with one control cabinet.

About Guangzhou HongCe Equipment

Guangzhou HongCe Equipment Co., Ltd started in 2003 as HongTong Electromechanical and has grown into a specialist supplier of electrical safety and materials test equipment for appliance, lighting, cable, and EV accessory manufacturers. Our engineers work from the standard text, not from a competitor's catalogue, which is why we can explain every dimension on the drawing you receive with the quotation.

Roughly two thirds of our machines are exported, with laboratories in Germany, Poland, Turkey, India, Vietnam, Thailand, Brazil, and Mexico using HongCe rigs in daily work. Technical questions are answered by the people who assembled the unit.

Related Equipment for a Complete IP Report
  • Oscillating tube rain test equipment for IPX3 and IPX4 clauses
  • IEC 61032 test probe and test finger sets for the touch safety clauses
  • Glow wire and needle flame apparatus for the fire hazard clauses of IEC 60598 and IEC 60335
  • Tracking index tester for CTI classification of enclosure materials