| Brand Name: | HongCe |
| Model Number: | HH0802 |
| MOQ: | 1 set |
| Price: | Negotiation |
| Payment Terms: | T/T,L/C |
| Supply Ability: | 10 sets per month |
If you test outdoor luminaires, garden equipment, EV charging enclosures or wall-mounted control boxes, the IPX3 and IPX4 clauses of IEC 60529 are usually the first water tests a notified body will run. This oscillating tube rain test equipment reproduces those two clauses with a swinging perforated tube, a regulated water supply and a programmable controller, so the same sample can be verified the same way in your lab, on the buyer's audit line, or during a third-party witness test.
HongCe has been building IP test rigs in Guangzhou since 2003, and this platform is the fourth generation of our tube machine. The mechanical layout has not changed much on purpose: engineers who have used an older rig can walk up to this one and start a run in five minutes. What did change is the water circuit and the control layer, and that is where most repeatability problems used to come from.
| Standards | IEC 60529:1989+AMD1:1999+AMD2:2013, GB/T 4208, EN 60529 |
| Tube radius options | R200, R400, R600, R800, R1000, R1200, R1600 mm (R1600 split into two half shells for shipping) |
| Nozzle hole diameter | Φ0.4 mm, laser drilled, hole spacing 50 mm |
| Swing angle | ±60° for IPX3, ±180° for IPX4, set on the touch screen |
| Swing speed | 60°/s or 12°/s depending on the clause selected in the recipe |
| Water flow | 0.07 L/min per hole (IPX3), 0.6 L/min per hole (IPX4), ±5% |
| Flow control | Closed loop, electromagnetic flow meter plus pressure regulator |
| Turntable | Φ600 mm stainless steel, 1 r/min, height adjustable 0-1000 mm |
| Controller | PLC + 7 inch colour touch screen, 50 recipes, run timer 0-999 min |
| Frame material | 304 stainless steel tube and plate, welded base with castors and levelling feet |
| Water supply | Soft water or filtered tap water, inlet pressure 0.1-0.4 MPa, drain outlet Φ50 mm |
| Power supply | AC 220 V 50/60 Hz, single phase, 1.5 kW (110 V version available) |
| Floor footprint | Approx. 2600 x 1200 x 2400 mm for R1000, weight 320 kg |
Three parts of this machine decide whether your IPX3 result will be accepted by a reviewer.
Water is recycled in a 200 L stainless reservoir with a removable filter basket. Sample wiring is routed through a sealed gland so you can power a luminaire during the run and check for ingress with the lamp lit.
| Comparison item | HongCe tube rig | Typical low cost rig | European brand rig |
| Flow stability | Closed loop flow meter, ±5% held during the run | Manual valve, drifts with supply pressure | Closed loop, comparable |
| Swing accuracy | Servo + encoder, angle set in software | Cam or limit switch, needs mechanical adjustment | Servo, comparable |
| Tube availability | R200 to R1600 stocked, spare tubes in 7 days | Often one radius only | Long lead time, high spare cost |
| Documentation | Clause mapping sheet, calibration report, English manual | Short manual, no clause mapping | Full documentation |
| Support model | Remote session within one working day, video commissioning | Email only | Regional agent, ticket queue |
| Budget level | Mid range, 40-60% of European list | Lowest | Highest |
We are not trying to be the cheapest tube machine on the market. The difference you pay for is the flow loop, the encoder and the fact that you can call an engineer who has actually assembled the unit.
![]()
Q: What is the real difference between IPX3 and IPX4 on this machine?
The code selects the swing angle and the flow per hole. IPX3 uses ±60° with 0.07 L/min per hole, IPX4 uses ±180° with 0.6 L/min per hole. Both are stored as separate recipes, so an operator cannot mix them by mistake.
Q: My sample is 1.8 m wide. Do I need R1600?
The tube radius must be small enough to keep the specified distance from the enclosure surface, and large enough to cover the sample. For most 1.8 m cabinets an R1000 tube with the sample rotated through four positions is accepted by test houses. We will calculate the geometry with you before you order, based on a photo and the outer dimensions.
Q: Can it also run IPX1 and IPX2?
Not with the tube. IPX1 and IPX2 need a drip box with a defined 1 mm/m and 3 mm/m rainfall. We can supply a drip box that mounts on the same frame as an option.
Q: Is the flow meter calibrated and traceable?
Yes. Each flow meter ships with a factory calibration sheet, and the third party certificate from SGS or CNAS accredited labs can be added at cost.
Q: How long from order to shipment?
Standard R200 to R1000 configurations ship in 20 to 25 days. R1200 and R1600 take 30 to 35 days because the tube is machined in two halves.
Q: What water quality do you recommend?
Filtered water below 200 μS/cm conductivity. Hard water will scale the Φ0.4 mm holes within a few months and the flow will drift even with the closed loop.
Guangzhou HongCe Equipment Co., Ltd was founded in 2003 as HongTong Electromechanical and has focused on electrical safety and materials test equipment since then. Our workshop assembles IP code rigs, glow wire and needle flame apparatus, tracking index testers, plug and socket test benches and custom fixtures for appliance and lighting manufacturers. Around 70% of our output goes to laboratories and factories outside China, including test houses in Germany, Turkey, India, Vietnam, Brazil and Mexico that use HongCe equipment as their day to day working standard.
If you need a clause specific fixture that does not exist as a catalogue item, our engineering team builds from the standard text and your sample drawing. Send a drawing or a sample photo with the clause number and you will get a dimensioned proposal, not a generic quotation.