| Brand Name: | HongCe |
| MOQ: | 1 Set |
| Payment Terms: | T/T, L/C at sight |
| Supply Ability: | 8 Sets per Month |
A finished battery pack cannot be evacuated, cannot be wetted and cannot be inspected seam by seam in a takt. The hood method is the only one of the three that keeps the pack dry, gives you a number, and fits a production shift — which is why this is the system we build for pack-level sealing verification.
Every leak testing method assumes something about the part. Vacuum chamber testing assumes the part can be evacuated, and a pack cannot — the cells, the structural foam and the seals are not designed for external vacuum, and pulling one down will damage it or, worse, deform it in a way that creates the leak you were testing for.
Water immersion assumes you can dry the part afterwards. On a high-voltage assembly, that assumption is unacceptable, and it leaves no record you can show a customer.
Air decay assumes a small, stiff, temperature-stable volume. A pack is the opposite: tens of litres, a lot of thermal mass, and an acceptance criterion that is usually far below what air can resolve in a shift let alone a takt.
The hood method sidesteps all three. The pack stays at ambient pressure, stays dry, and the measurement is a tracer gas concentration rather than a pressure difference — so the material and the volume stop fighting the test.
The pack goes into a sealed hood of known volume and is charged with a helium mixture through its service port. Anything that escapes accumulates in the hood. A circulation fan mixes the hood atmosphere so there are no dead zones, and a mass spectrometer samples that atmosphere and measures the rise over a fixed window.
The key point, and the one that decides your cycle time: sensitivity is governed by accumulation time, not by the analyser alone. Doubling the dwell roughly doubles the signal. There is always a trade between the two, and it should be your trade — we will tell you the shortest dwell that honestly meets your criterion instead of quoting a sensitivity number in isolation.
Two practical details make the difference between a stable result and an argument. First, the hood atmosphere is monitored between cycles: a workshop where a cylinder has been venting will otherwise drift the readings all morning. Second, the hood and the pack are both recovered, because on a large volume the pack itself holds most of the gas.
A hood that is much larger than the pack dilutes the signal and buys you nothing. We size the hood to the pack envelope with enough clearance for loading, not to a round number.
Helium is light and will stratify. Without a fan and a baffle arrangement the sample point reads whatever is local to it. Our hoods circulate and were checked for dead zones during commissioning, not assumed.
Ambient helium compensation is not a nice-to-have on a pack line; it is the difference between a usable limit and a permanent argument with your quality team.
Both are evacuated back through the recovery loop after the measurement. Without that, a large-volume pack vents its whole charge every cycle and the running cost quietly becomes the biggest number in the business case.
Pack volume, charge pressure and dwell all change with the product. Recipes are selected by barcode so nobody edits parameters at the station.
| Item | Specification |
|---|---|
| Method | Accumulation hood with mass spectrometer measurement |
| Hood sizes | 1200 × 800 × 400 mm standard; 2000 × 1500 × 400 mm and larger on request |
| Minimum detectable leak | 1.0×10-6 mbar·L/s, dependent on accumulation time |
| Typical cycle time | 6 – 10 min per pack including charge, dwell and recovery |
| Helium concentration | 10% – 100%; 10% or 20% mixture commonly used |
| Mixing | Internal circulation fan with baffle design, dead zones checked at commissioning |
| Background control | Ambient helium monitoring with automatic compensation between cycles |
| Helium recovery | ≥90% from hood and pack, integrated recovery and purification |
| Control | PLC with 15-inch HMI, 100 recipes, multi-level access |
| Traceability | Barcode scan, per-pack record, MES upload over Ethernet |
| Calibration | Automatic sequence with calibrated leak, 12-month interval |
| Power supply | AC 380 V, 3-phase, 50/60 Hz, 15 kW |
| Compressed air | 0.6 MPa dry, oil-free |
| Weight | About 2200 kg |
| Test item | Typical defect | What the customer sees |
|---|---|---|
| Pack housing weld seams | Porosity, incomplete penetration, spatter-induced lack of fusion | Water ingress, isolation fault |
| Sealant and adhesive beads | Gaps, insufficient compression, cure voids | Moisture in the pack after a wash |
| Service cover gaskets | Under-torque, twisted gasket, damaged lip | Condensation on the cover |
| Connector feed-throughs | Seal damage during assembly, pin cavity leaks | Corrosion at the connector |
| Coolant port joints | Thread and O-ring defects | Coolant loss, pressure fault codes |
| Pressure relief and vent valves | Seat leakage, wrong cracking pressure | Fogging or pressure imbalance |
| Module interfaces | Leaks between sub-assemblies | Hard to trace later — which is the point of testing now |
Pack customers usually arrive with an IP67 or IP6K9K requirement and no leak rate, and expect a conversion table. There is no universal one, because it depends on pack volume and on the pressure profile the standard applies. What works is an empirical correlation on your own packs:
| Method | Sensitivity | Pack wetted | Cycle | Operator dependence |
|---|---|---|---|---|
| Accumulation hood, this machine | 1×10-6 mbar·L/s | No | 6–10 min | Low |
| Vacuum chamber | 1×10-9 mbar·L/s | No | Not feasible on a finished pack | Low |
| Air pressure decay | About 1×10-3 mbar·L/s | No | 10–30 min at pack volume | Medium |
| Water immersion or bubble | Gross leaks only | Yes | 5–15 min | High |
| Helium sniffer spray | 1×10-7 mbar·L/s | No | 5–20 min | High |
If the pack design allows evacuation, a vacuum chamber is faster and more sensitive and you should buy one. It is the sealed pack with a large internal volume that makes the hood the practical answer — and that describes almost every finished pack we have been asked about.
Because the chamber method requires evacuating the part. A pack is not designed for external vacuum: cells, structural elements and seals can be damaged, and any deformation invalidates the test. The hood keeps the pack at ambient pressure and measures what leaks out instead.
Six to ten minutes is typical. Shortening the dwell raises the minimum detectable leak, because the signal grows with accumulation time. Give us the acceptance criterion and we will give you the shortest dwell that still meets it honestly.
Ten or twenty percent in nitrogen is common for packs: it keeps cost and supply risk down and is safe to handle. The controller compensates for concentration, so results stay comparable between mixtures.
It can, which is why the hood monitors ambient helium between cycles and pauses if the background is too high. Keep cylinder venting away from the station, and give the area a few minutes after a burst hose — same discipline as any tracer gas installation.
Yes. Roller or chain conveyor through the hood, automatic lid actuation and a handshake with the line PLC are standard options. Most customers start with manual loading and automate the second line.
The hood and the pack are both drawn through the recovery and purification loop and returned to the buffer tank. On a pack the pack itself holds most of the charge, so recovering only the hood would be a false economy.
The hood measures the whole sealed envelope, so a coolant port leak will show. If you need the circuit isolated and tested at higher pressure, we can add a dedicated circuit and a second recipe — say so at the enquiry stage, because it changes the fixture.
Pack envelope, internal volume, service port details, target leak rate or IP requirement, and the takt you need to hit. With those five numbers we can size the hood and give you a cycle time rather than a range.
We have built leak detection and electrical test equipment in Guangzhou since 2003, with 50–100 employees and roughly half of our output exported to Europe, North America and Southeast Asia. Our team commissions chamber systems, tracer gas hoods and air decay testers, so the method recommendation comes from production experience across all three rather than from a single product line.
Every system is assembled, leak-checked against a calibrated standard and recorded under its serial number before shipment. That record is still available years later when a customer needs to compare a new result with the original acceptance data.