Most parts that need a leak test do not need helium. They need a number, a repeatable verdict and a cost per test close to zero. This is the machine for that band of work: dry compressed air, differential measurement against a master part, two independent channels, and a controller that refuses to blame the part when the fixture is at fault.
A helium system is not expensive because of the analyser. It is expensive because every single test consumes a gas that has to be bought, stored, recovered and purified, and because the vacuum hardware that makes the measurement possible needs maintenance.
On a part where the criterion is a bubble count or a millilitre per minute, that money buys you nothing. A pressure decay test on the same part uses shop air and electricity. For a mid-size valve body tested twice a minute, two shifts a day, the difference is not a rounding error — it is a line item that shows up in the annual cost review.
The honest framing is this: spend on helium where it changes a decision, and spend nothing extra where it does not. Many of our customers run an air tester at the end of the line as the routine gate, and keep a helium chamber in the lab for design validation and for the parts that fail.
Air testing resolves gross and medium leaks — roughly 1×10-3 mbar·L/s and above, depending on part volume and the time you are willing to give it. That covers the overwhelming majority of production defects: a missing O-ring, a porous casting, a cracked weld, a valve seat that never lapped in.
What it cannot see is the fine band — the hairline braze void, the moulding weld line that weeps under thermal cycling, the seal that passes today and fails in eighteen months. If your customer's criterion lives in that band, no amount of clever signal processing will rescue an air test, and you should be buying helium.
Two identical parts, one known good, are filled to the same pressure and isolated. The sensor reads the difference between them, not an absolute pressure. Ambient temperature drift, which is the single biggest source of false rejects in air testing, affects both sides and cancels. Resolution is 0.1 Pa on the difference.
A damaged fixture seal looks exactly like a leaking part. The controller tests the fixture itself before every run and refuses to judge the part if the fixture fails. This one feature removes most of the "the machine is wrong" conversations we used to have.
Compressing air heats it, and the part cools back down over the first seconds of the test. That curve looks like a leak to a naive algorithm. The controller models the transient and waits for the slope to settle before it starts measuring.
Some failures are the opposite of a leak: a blocked passage. The same pneumatics can hold a fixed pressure and measure flow, which catches swarf, flash and a seal that has been fitted the wrong way round.
| Item | Specification |
|---|---|
| Test methods | Pressure decay, differential pressure decay, vacuum decay, flow (blocked passage) |
| Pressure range | 5 – 1000 kPa (0.05 – 10 bar); lower ranges on request |
| Sensor | Differential pressure, 0.1 Pa resolution, ±0.1% F.S. accuracy |
| Test channels | 2 independent, separate fixtures and limits |
| Programs | 200, password protected, barcode selectable |
| Typical cycle | 5 – 120 s depending on part volume and criterion |
| Display | 10-inch colour touch screen, multi-language |
| Data | SPC trend, pass/fail statistics, CSV export, operator login |
| Interfaces | USB, RS485, Ethernet (Modbus TCP), barcode scanner port |
| Air supply | 0.6 – 0.8 MPa dry, clean, oil-free |
| Power supply | AC 220 V, 50/60 Hz, 200 W |
| Dimensions / weight | 480 × 400 × 1250 mm cabinet, 60 kg |
| Test item | Method | Typical band |
|---|---|---|
| Through-leak in a casting or weld | Pressure decay | 1 – 50 mL/min |
| Valve seat leakage | Differential pressure | 0.5 – 10 mL/min |
| Gasket and O-ring seat leaks | Differential pressure | 1 – 20 mL/min |
| Missing or mis-seated seal | Fast pressure ramp | Gross leak |
| Blocked internal passage | Flow test | Flow below set minimum |
| Enclosure ingress risk | Pressure decay on the sealed box | IP65 / IP66 / IP67 equivalent |
| Cracked or porous part | Both, with pressure ramp | Gross to medium |
| Criterion | This air tester | Helium vacuum system | Bubble / immersion |
|---|---|---|---|
| Detectable band | About 1×10-3 mbar·L/s and above | To 1×10-9 mbar·L/s | Gross leaks only |
| Cost per test | Air and electricity | Helium plus vacuum upkeep | Air and electricity |
| Cycle | 5 – 120 s | 30 – 60 s | 30 s – minutes |
| Locates the leak | No | Yes, in probe mode | Roughly |
| Part condition | Must be dry | Must be dry | Gets wet |
| Sensitivity to operator | Low | Medium | High |
Two to three orders of magnitude less. That sounds like a lot, and it is — but it only matters if your criterion lives in that band. Most production defects are gross or medium leaks, and for those the air tester is faster, cheaper and just as decisive.
For differential mode, yes. It should be a genuine production part that has passed every other check. We recommend two: one good part, and one with a calibrated leak orifice for verification.
Badly. Water in a passage evaporates under pressure and looks like a leak. Dry the part, or accept a longer stabilisation time — if the process cannot avoid wet parts, tell us and we will advise whether a different method suits you better.
A 50 mL valve body is typically 15 to 25 seconds. Large volumes need longer because the pressure has to settle first. The live curve on screen tells you whether you are limited by the part or by the test time.
Yes, over Modbus TCP, or by CSV export with barcode-linked records. For most customers the requirement is simply that each result is tied to a serial number, and that is standard.
Possible, but the fixture becomes the hard part and the cycle grows quickly. For large volumes with a tight criterion, an accumulation or tracer gas method is usually cheaper to run. Send us the volume and we will say which route we would take.
It is the main risk in air testing, which is why the differential arrangement exists. Keep the master and the part in the same air, avoid a station next to a door or a furnace, and the compensation has little left to do.
Yes — two independent channels with separate fixtures, limits and recipes. Useful when a line runs two part numbers and you do not want two cabinets.
We have built test equipment in Guangzhou since 2003, with 50–100 staff and about half of our output exported. Our range covers electrical safety testers, material test machines and leak detection — air, helium and tracer gas — which means the recommendation you get is based on what fits the part rather than on what we happen to have in stock.
Machines are assembled, pressure-tested and calibrated before shipment, and each one is recorded under its serial number so a question about a five-year-old unit can still be answered with data rather than a guess.