Air Leak Testing Equipment Pressure Decay Airtightness Tester 0.1 Pa Resolution For Valve Pipe Assemblies

Air Leak Testing Equipment Pressure Decay Airtightness Tester 0.1 Pa Resolution For Valve Pipe Assemblies

Brand Name: HongCe
MOQ: 1 Set
Payment Terms: T/T, L/C at sight, Western Union
Supply Ability: 40 Sets per Month
Detail Information
Place of Origin:
Guangdong, China
Certification:
CE, ISO 9001:2015
Test Methods:
Pressure Decay, Differential Pressure, Vacuum Decay, Flow Test
Pressure Range:
5 - 1000 KPa (0.05 - 10 Bar)
Sensor Resolution:
0.1 Pa Differential
Accuracy:
+/- 0.1% F.S.
Test Channels:
2 Independent
Program Storage:
200 Programs, Barcode Selectable
Typical Cycle Time:
5 - 120 S
Interfaces:
USB, RS485, Ethernet Modbus TCP
Air Supply:
0.6 - 0.8 MPa Dry Oil-free
Power Supply:
AC 220 V, 50/60 Hz, 200 W
Packaging Details:
Plywood case with internal bracing, air-bubble wrap on touch screen, ISPM-15 marked pallet
Highlight:

Pressure Decay Airtightness Tester

,

Dry Air Leak Testing Equipment

,

Differential Pressure Leak Measurement

Product Description
Sensor resolution0.1 Pa differential
Pressure range5–1000 kPa
Channels2 independent
Cost per testCompressed air only

Most parts that need a leak test do not need helium. They need a number, a repeatable verdict and a cost per test close to zero. This is the machine for that band of work: dry compressed air, differential measurement against a master part, two independent channels, and a controller that refuses to blame the part when the fixture is at fault.

This machine is the right purchase if

  • Your drawing says "no bubbles in 60 seconds", "less than 5 mL/min" or an IP65/66/67 requirement.
  • You test valves, castings, housings, filters, pumps or sealed enclosures in volume.
  • You are paying for helium on parts where the acceptance criterion is a gross or medium leak.
  • You need traceability and SPC data without building a metrology department.

Look elsewhere if

  • The specified rate is below about 1×10-4 mbar·L/s — that is helium territory.
  • Your parts arrive wet or oily and nobody can dry them.
  • Your part is a large sealed pack with a tiny allowable leak — the test time becomes unworkable.

Where the money actually goes

A helium system is not expensive because of the analyser. It is expensive because every single test consumes a gas that has to be bought, stored, recovered and purified, and because the vacuum hardware that makes the measurement possible needs maintenance.

On a part where the criterion is a bubble count or a millilitre per minute, that money buys you nothing. A pressure decay test on the same part uses shop air and electricity. For a mid-size valve body tested twice a minute, two shifts a day, the difference is not a rounding error — it is a line item that shows up in the annual cost review.

The honest framing is this: spend on helium where it changes a decision, and spend nothing extra where it does not. Many of our customers run an air tester at the end of the line as the routine gate, and keep a helium chamber in the lab for design validation and for the parts that fail.

What pressure decay can see, and what it cannot

Air testing resolves gross and medium leaks — roughly 1×10-3 mbar·L/s and above, depending on part volume and the time you are willing to give it. That covers the overwhelming majority of production defects: a missing O-ring, a porous casting, a cracked weld, a valve seat that never lapped in.

What it cannot see is the fine band — the hairline braze void, the moulding weld line that weeps under thermal cycling, the seal that passes today and fails in eighteen months. If your customer's criterion lives in that band, no amount of clever signal processing will rescue an air test, and you should be buying helium.

A rule of thumb from twenty years of applications: if the specified leak rate has fewer than four zeros in front of it (1×10-4 mbar·L/s or smaller), ask for helium. If it has three or fewer, ask what air would cost you first.

The four design details that decide whether the result is real

Differential measurement against a master part

Two identical parts, one known good, are filled to the same pressure and isolated. The sensor reads the difference between them, not an absolute pressure. Ambient temperature drift, which is the single biggest source of false rejects in air testing, affects both sides and cancels. Resolution is 0.1 Pa on the difference.

Fixture seal verification

A damaged fixture seal looks exactly like a leaking part. The controller tests the fixture itself before every run and refuses to judge the part if the fixture fails. This one feature removes most of the "the machine is wrong" conversations we used to have.

Temperature compensation on the fill transient

Compressing air heats it, and the part cools back down over the first seconds of the test. That curve looks like a leak to a naive algorithm. The controller models the transient and waits for the slope to settle before it starts measuring.

Flow test as a second mode

Some failures are the opposite of a leak: a blocked passage. The same pneumatics can hold a fixed pressure and measure flow, which catches swarf, flash and a seal that has been fitted the wrong way round.

How a cycle runs

  • Load and clamp — part into the fixture, barcode scan, pneumatic clamp closes the seals.
  • Fixture check — the controller verifies its own seals before pressurising the part.
  • Fill and stabilise — air to the recipe pressure, then a settle window while the thermal transient decays.
  • Measure — differential pressure is logged over the test window and converted to a leak rate; the verdict is compared against the limit.
  • Release and record — part released, result stored with serial number, SPC trend updated.

Technical parameters

ItemSpecification
Test methodsPressure decay, differential pressure decay, vacuum decay, flow (blocked passage)
Pressure range5 – 1000 kPa (0.05 – 10 bar); lower ranges on request
SensorDifferential pressure, 0.1 Pa resolution, ±0.1% F.S. accuracy
Test channels2 independent, separate fixtures and limits
Programs200, password protected, barcode selectable
Typical cycle5 – 120 s depending on part volume and criterion
Display10-inch colour touch screen, multi-language
DataSPC trend, pass/fail statistics, CSV export, operator login
InterfacesUSB, RS485, Ethernet (Modbus TCP), barcode scanner port
Air supply0.6 – 0.8 MPa dry, clean, oil-free
Power supplyAC 220 V, 50/60 Hz, 200 W
Dimensions / weight480 × 400 × 1250 mm cabinet, 60 kg

What it finds

Test itemMethodTypical band
Through-leak in a casting or weldPressure decay1 – 50 mL/min
Valve seat leakageDifferential pressure0.5 – 10 mL/min
Gasket and O-ring seat leaksDifferential pressure1 – 20 mL/min
Missing or mis-seated sealFast pressure rampGross leak
Blocked internal passageFlow testFlow below set minimum
Enclosure ingress riskPressure decay on the sealed boxIP65 / IP66 / IP67 equivalent
Cracked or porous partBoth, with pressure rampGross to medium

Setting the limit without guessing

  • Use a real master part, not a solid block. A block cancels temperature drift but ignores the compliance of the actual part, and the reading becomes optimistic.
  • Calibrate with an orifice, not an opinion. Fit a known leak standard in place of the part and confirm the machine reads what it should. Repeat it monthly; it takes ten minutes.
  • Pick the test time from data. Run ten good parts and ten rejects. If the two populations overlap, lengthen the test rather than tightening the limit — a tighter limit on a noisy measurement just rejects good parts.
  • Write the method on the drawing. Pressure, stabilisation time, test time, and the reference part. A limit without a method cannot be audited.

Compared with the alternatives

CriterionThis air testerHelium vacuum systemBubble / immersion
Detectable bandAbout 1×10-3 mbar·L/s and aboveTo 1×10-9 mbar·L/sGross leaks only
Cost per testAir and electricityHelium plus vacuum upkeepAir and electricity
Cycle5 – 120 s30 – 60 s30 s – minutes
Locates the leakNoYes, in probe modeRoughly
Part conditionMust be dryMust be dryGets wet
Sensitivity to operatorLowMediumHigh

Delivery, installation and the first month

  • Fixture concept reviewed against your part drawing before the order is confirmed.
  • Master part selection and reject-limit study during commissioning, on your own parts.
  • Orifice calibration and a repeatability run, documented for your quality file.
  • Operator training on loading, reading the curve and what to do when the fixture check fails.
  • 24-month warranty on controller and pneumatics.
  • Spares in Guangzhou: seals, solenoid valves, pressure sensors, touch screens — 48-hour dispatch.
  • MES handshake over Modbus TCP, with barcode login for traceability.
  • Annual calibration against a certified pressure standard.

Frequently asked questions

How does the sensitivity compare with helium, honestly?

Two to three orders of magnitude less. That sounds like a lot, and it is — but it only matters if your criterion lives in that band. Most production defects are gross or medium leaks, and for those the air tester is faster, cheaper and just as decisive.

Do I have to supply a master part?

For differential mode, yes. It should be a genuine production part that has passed every other check. We recommend two: one good part, and one with a calibrated leak orifice for verification.

Can it test a part that comes off the line wet?

Badly. Water in a passage evaporates under pressure and looks like a leak. Dry the part, or accept a longer stabilisation time — if the process cannot avoid wet parts, tell us and we will advise whether a different method suits you better.

How long does a test take?

A 50 mL valve body is typically 15 to 25 seconds. Large volumes need longer because the pressure has to settle first. The live curve on screen tells you whether you are limited by the part or by the test time.

Can the results go into our MES?

Yes, over Modbus TCP, or by CSV export with barcode-linked records. For most customers the requirement is simply that each result is tied to a serial number, and that is standard.

What about very large sealed parts, like a cabinet?

Possible, but the fixture becomes the hard part and the cycle grows quickly. For large volumes with a tight criterion, an accumulation or tracer gas method is usually cheaper to run. Send us the volume and we will say which route we would take.

Will a temperature change in the shop affect the result?

It is the main risk in air testing, which is why the differential arrangement exists. Keep the master and the part in the same air, avoid a station next to a door or a furnace, and the compensation has little left to do.

Can one machine run two different parts at once?

Yes — two independent channels with separate fixtures, limits and recipes. Useful when a line runs two part numbers and you do not want two cabinets.

About Guangzhou Hejin Automation Control Technology

We have built test equipment in Guangzhou since 2003, with 50–100 staff and about half of our output exported. Our range covers electrical safety testers, material test machines and leak detection — air, helium and tracer gas — which means the recommendation you get is based on what fits the part rather than on what we happen to have in stock.

Machines are assembled, pressure-tested and calibrated before shipment, and each one is recorded under its serial number so a question about a five-year-old unit can still be answered with data rather than a guess.

Send the part drawing, the working pressure, the internal volume and the acceptance criterion from your drawing. We will come back with a test concept, an estimated cycle time and a quotation — usually within one working day.