Product Details:
Place of Origin: China
Brand Name: HongCe
Certification: Third part calibration certificate(cost additional)
Model Number: HH0811
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiatable
Packaging Details: Plywood
Delivery Time: 25 days
Payment Terms: L/C, T/T
Supply Ability: 15 sets per month
Contact Now
Detailed Product Description
Working Volume: 150L Temperature Range: -40 ℃~ +150 ℃
Humidity Range: 20 %RH~ 98 %RH
High Light:

iec testing equipment

,

laboratory test equipment

IEC 60335 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃,

20 %RH~ 98 %RH

 

 

Standard

 

IEC60335-2-17, Clause 21.110.3, Clause 21.111.2.

 

Application

 

It is used to process the aging test for the blanket’s flexible fabric parts.

 

Test sample

 

Blanket’s flexible fabric parts.

 

Feature

 

Box type

 

Parameters

 

Product Name Programmable Temperature Humidity Chamber
Volume, size and weight
Working Volume 150L (can be customized)
Inner size W500mm × H600mm × D500mm
Outer size W1020mm × H1000mm × D1460mm
Weight 300KG
Performance
Test environmental conditions Environmental temperature +5~+28℃, relative humidity≤85%, under the condition that no sample inside the test chamber
Test method According to IEC60068-2, IEC60598-1
Temperature range -40℃~+150℃
Temperature control precision ±0.2℃
Humidity control precision ±2.5% RH
Temperature uniformity ±2℃
Humidity uniformity ±3.0% RH
Heating up time 3℃/min (Average heating up rate)
Cooling down time 1℃/min (Average cooling down rate)

 

*Note: Please refer to below humidity use range chart!

 

IEC60335-2-17 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃,20 %RH~ 98 %RH 0

4. Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH.

* To guarantee above 2~4 performance, should be measured 30 minutes after the temperature sensing measurements is stable!

 

5. Temperature and humidity distribution uniformity: ±2℃; ±3%RH.

*Note: To guarantee below 6~11 performance, the measuring positions should be each wall’s 1/6 positions of the test zone, and should be measured 30 minutes after the temperature is stable!

 

6. Heating time: Heating from the room temperature to 150℃, the total heating time is 50 mins (under non-load state).

 

7. Cooling time: Cooling from the room temperature to -40℃, the total cooling time is 40mins (under non-load state).

 

8. Inner chamber dimensions: test area: 50×60×50cm(W×H×D).

*Note: The volume of placing samples should not exceed 2/3 of the capacity of the test zone.

 

9. Equipment installation space: at least 920×1600×870cm(W×H×D).

 

10. Test chamber door: 80 × 105 cm(W×H), total 1.

 

11. Power source: AC 1220 V 50 Hz MAX 40 A

 