Place of Origin: | China |
Brand Name: | HongCe |
Certification: | Third part calibration certificate(cost additional) |
Model Number: | HH0811 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiatable |
Packaging Details: | Plywood |
Delivery Time: | 25 days |
Payment Terms: | L/C, T/T |
Supply Ability: | 15 sets per month |
Working Volume: | 150L | Temperature Range: | -40 ℃~ +150 ℃ |
---|---|---|---|
Humidity Range: | 20 %RH~ 98 %RH | ||
High Light: | iec testing equipment,laboratory test equipment |
IEC 60335 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃,
20 %RH~ 98 %RH
Standard
IEC60335-2-17, Clause 21.110.3, Clause 21.111.2.
Application
It is used to process the aging test for the blanket’s flexible fabric parts.
Test sample
Blanket’s flexible fabric parts.
Feature
Box type
Parameters
Product Name | Programmable Temperature Humidity Chamber |
Volume, size and weight | |
Working Volume | 150L (can be customized) |
Inner size | W500mm × H600mm × D500mm |
Outer size | W1020mm × H1000mm × D1460mm |
Weight | 300KG |
Performance | |
Test environmental conditions | Environmental temperature +5~+28℃, relative humidity≤85%, under the condition that no sample inside the test chamber |
Test method | According to IEC60068-2, IEC60598-1 |
Temperature range | -40℃~+150℃ |
Temperature control precision | ±0.2℃ |
Humidity control precision | ±2.5% RH |
Temperature uniformity | ±2℃ |
Humidity uniformity | ±3.0% RH |
Heating up time | 3℃/min (Average heating up rate) |
Cooling down time | 1℃/min (Average cooling down rate) |
*Note: Please refer to below humidity use range chart!
4. Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH.
* To guarantee above 2~4 performance, should be measured 30 minutes after the temperature sensing measurements is stable!
5. Temperature and humidity distribution uniformity: ±2℃; ±3%RH.
*Note: To guarantee below 6~11 performance, the measuring positions should be each wall’s 1/6 positions of the test zone, and should be measured 30 minutes after the temperature is stable!
6. Heating time: Heating from the room temperature to 150℃, the total heating time is 50 mins (under non-load state).
7. Cooling time: Cooling from the room temperature to -40℃, the total cooling time is 40mins (under non-load state).
8. Inner chamber dimensions: test area: 50×60×50cm(W×H×D).
*Note: The volume of placing samples should not exceed 2/3 of the capacity of the test zone.
9. Equipment installation space: at least 920×1600×870cm(W×H×D).
10. Test chamber door: 80 × 105 cm(W×H), total 1.
11. Power source: AC 1 ∮ 220 V 50 Hz MAX 40 A