Send Message
Home ProductsHelium Leak Testing Equipment

Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec

Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec

  • Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec
  • Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec
  • Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec
  • Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec
Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec
Product Details:
Place of Origin: Made in China
Brand Name: HongCe
Certification: CE, ROSH, FCC(cost additional)
Model Number: HJBD01
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiatable
Packaging Details: Plywood
Delivery Time: 3 months
Payment Terms: L/C, T/T, Western Union
Contact Now
Detailed Product Description
Workpiece: Power Relay Tracer Gas: Helium
Vacuum Chamber Type: Bell Type Test Cycle: 90s/5pcs
Rejection Rate: 1.0×10-9Pa.m3/sec
High Light:

helium leak detection

,

helium leak testing

Vacuum Chamber Helium Leak Detection System for New Energy Vehicles Power Relay 

 

The equipment has 3 vacuum chambers that operate in tandem , thus, only one operator can run the equipment.
The workpiece is automatically detected in a vacuum chamber. The vacuum chamber adopts a bell-type structure and can be opened and closed automatically. The operator only needs to load and unload the workpieces, and the loading and unloading are simple and convenient.
Up to 5 workpieces can be installed on the fixture in vacuum chamber at a time. If there is no need to install 5 workpieces, the corresponding workpiece mounting holes can be plugged with plugs.
The German INFICON leak detector is used for inspection, and the maximum leak detection accuracy can reach 5 x 10-12 Pa.m3/s. Gross leaks and fine leaks can be identified during detection process, saving helium gas consumption.
Adopt imported brand vacuum pumps, to achieve a leak detection accuracy of 10-9 Pa.m3/sec and 90-second detection cycle, the system is equipped with a rough pump, a fine pump, and a leak detection pump. The vacuum of the leaking pump group can reach 10-6Pa. HongCe has experience in automated helium leak detection systems with 10-10Pa.m3/sec accuracy.
The short distance between the valve and the workpiece is sufficient to reduce the production cost. The connection between the workpiece and the equipment has a filter to prevent the contaminants in the workpiece from clogging the valve.
The system is controlled by the PLC. And display a variety of information on 10” color touch screen.
With a computer, and with two-dimensional workpiece code scanning & information storage system: combined by a two-dimensional scanning code reader and a computer, read the workpiece data, product code, detection time, operator, total production, good yield, not Good yield, etc. by the two-dimensional code, and can export EXCEL files, the software has a variety of models to meet the specifications and parameter memory. The operation is simple and convenient.
With safety protection , emergency stop and reset functions.
Equipment design meets ergonomic requirements.

 

 

Basic technical indicators:

 

Workpiece

Electric Automotive Power Relays

(The surface of the product to be inspected needs to be cleaned and dried.)

Vacuum Chamber Type Bell type
Vacuum Chamber Size 140*450*140mm
Quantity of Vacuum Chamber 3
Quantity of Fixture

3 sets, 1 set per each vacuum chamber

One to five products can be installed on 1 set of fixtures at a time, the vacant positions are plugged with plugs

If only one work piece is installed in the chamber, the installation holes of the other four workpieces are plugged with plugs.

The connection between the fixture and the workpiece is fast and automatic.

The fixture needs to be replaced when the product is changed (the exchange of fixtures needs to be completed in 10 minutes)

Gas for Fine Leak Test Helium
Gas Pressure for Fine Leak Test <0.7MPa, adjustable
Helium Recovery No (Optional)
Test Cycle 90s/5pcs (3 vacuum chambers work linkage, each chamber contains 5 pcs, on average every 90 seconds to finish 5 chamber detections, including 20s loading & unloading time)
Rejection Rate 1.0×10-9Pa.m3/sec
 
Operation Processes Chart:
 
Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec 0
 
Our this system has won "High-Tech Product" certificate:
Vacuum Chamber Helium Leak Testing Equipment for Electric Automotive Power Relay 1.0×10-9Pa.m3/sec 1

 

Contact Details
Guangzhou HongCe Equipment Co., Ltd.

Contact Person: Tessa Huang

Tel: +8618933919125

Fax: 86-020-31143909-805

Send your inquiry directly to us (0 / 3000)

Best Products