Product Details:
Payment & Shipping Terms:
|
Burning Time: | 9999X0.1S | Burning Angle: | Tilt 45°±2°, Adjustable |
---|---|---|---|
Blast Burner: | Comply IEC60695-11-2 | Combustion Chamber: | 300×450×1200±25mm |
Highlight: | flammability chamber,flame test equipment |
Button Operation Single Insulated Wire Flammability Testing Equipment For IEC60332 With Digital Indicator Brass Burner
Standard:
IEC60332-1-1 ‘Tests on electric and optical fibre cables under fire conditions – Part 1- 1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus’. IEC60332-1-2 ‘Tests on electric and optical fibre cables under fire conditions – Part 1- 2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame’. IEC60332-1-3 ‘Tests on electric and optical fibre cables under fire conditions – Part 1- 3: Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles’.
Application:
It simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. Suitable for vertical burning test of single cable or optical cable products, determine the combustion characteristics of insulating materials.
Feature:
This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, stainless steel of box full, large observation window, imported digital indicator of high precision, nice appearance. And they gather a number of advantages of similar products home and abroad.
Parameters:
Working voltage | 220V/60Hz |
Control operation mode | Electrical control, button operation |
Blast burner standard | IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass |
Gas flow and gas category | Mixture gas: 650±30mL/min propane;10±0.5L/min air,Dual flow meter adjustment |
Burning time | 9999X0.1S |
Burning angle | Tilt 45°±2°, Adjustable |
Test flame calibration | Temperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g |
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100° | |
Distance between the bunsen burner port to temperature measuring copper block:95 mm | |
Flame height: Inner flame:55±5mm, outer flame:180±10mm | |
Temperature rise time from 100±5°C to 700°±3°C 45±5s | |
Combustion chamber | WDH=300×450×1200±25mm |
Gas | >95% propane or coal gas |
Test sample | Length: 600±25mm, distance from the bottom:50mm |
Fixed horizontal support of the sample | 2, distance:550mm |
Dimension | WDH=700×450×1350mm, weight about 120kg |
Contact Person: Ms. Tessa Huang
Tel: +86 18933919125
Fax: 86-020-31143909-805