Product Details:
Place of Origin: China
Brand Name: HongCe
Certification: Calibration Certificate (cost additional)
Model Number: SH-1/SH-2/SH-5/SH-6
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: Aluminum box
Delivery Time: 7 days
Payment Terms: T/T
Supply Ability: 100 set/ month
Contact Now
Detailed Product Description
Product Name: Spring Operated Impact Hammer Impact Energy: 0.14, 0.2, 0.35, 0.5, 0.7, 1 J, 2J
Impact Element Mass: 250g±5g Or 500g±5g Material: Stainless Steel, Polyamide
Standard: IEC60068-2-75, IEC60335-1, IEC60598-1 And Etc. Application: Impact Resistance Test
Model: Single Energy Or Adjustable Energy IK Ratings: IK02, IK03, IK04, IK05, IK06
High Light:

IEC 60068-2-75 Impact Testing Machine

,

IK06 Impact Testing Machine

,

1J Spring Operated Impact Hammer

IEC 60068-2-75 Impact Testing Machine - 1J Spring Operated Impact Hammer

 

Example of spring hammer test apparatus
Figure E.1 shows an example of a spring hammer test apparatus complying with Clause 5, for energies not exceeding 1 J. The mass of the body assembly is 1250 g ± 10 g. The hammer head is fixed to the hammer shaft in such a way that the distance from its tip to the plane of impact (the plane of the cone truncation), when the striking element is on the point of release, has approximately the value shown for the spring compression in Table E.1 .                     Impact Testing Machine

The cone has a mass of approximately 60 g and the cone spring is such that it exerts a force of approximately 5 N when the release jaws are on the point of releasing the striking element. The release mechanism springs are adjusted so that they exert just sufficient pressure to keep the release jaws in the engaged position.                                                                                          Impact Testing Machine
The apparatus is cocked by pulling the cocking knob back until the release jaws engage with the groove in the hammer shaft. The release cone of the test apparatus is pushed against the prescribed position(s) on the specimen, perpendicular to the surface of the specimen. The pressure is slowly increased so that the cone moves back relative to the body of the apparatus until it is in contact with the release bars, which then move to operate the release mechanism and allow the hammer to strike the specimen.

                                                                           Impact Testing Machine

Standard: IEC 60068-2-63, IEC 60068-2-75 test Ehb, IEC 60335-1, IEC 60598-1, IEC 60950, and IEC 60065

Application: This device is intended to test the impact resistance to shell, operating arm, handle, knob, indicator lights and shades of electrical appliance for household or similar purpose, to verify the safety performance and strength of the product.

Test sample: Shell, operating arm, handle, knob, indicator lights and shades

 

Feature:

1. The impact hammer is composed of three parts:

A. Shell. Includes housing, impact element guide and release mechanism, and parts fixed on these parts.

B. Impact element. Including the hammer, hammer tail and firing handle.

C. Release cone.

2. Working principle

The hammer generate impact energy by the mass and movement of impact element. When pulling the operating handle, release claw stop at the impact element release point, the hammer spring is pressed, when the compression quantity is different, the spring will release the different energy. For multi energy impact hammer, rotate the end cover to select corresponding impact energy. The impact energy was calibrated on calibration facility before delivery.                              Impact Testing Machine

 

Parameters:

Model SH-0.14/SH-0.2/SH-0.35/SH-0.5/SH-0.7/SH-1 SH-2 SH-5 SH-6
Impact energy(J) 0.14; or 0.2; 0.35; 0.5; 0.7; 1.0 2±0.1 0.2 and 0.35, 0.5, 0.7, 1 0.14 and 0.2, 0.35, 0.5, 0.7, 1
Impact element mass 250g±5g 500g±5g 250g±5g 250g±5g
Overall mass 1250g±10g 1500g±10g 1450g±10g 1450g±10g
Material Stainless steel

Stainless steel

Impact Testing Machine

Stainless steel Stainless steel

IEC 60068-2-75 Impact Testing Machine - 1J Spring Operated Impact Hammer 0 

IEC 60068-2-75 Impact Testing Machine - 1J Spring Operated Impact Hammer 1

Contact Details
Guangzhou HongCe Equipment Co., Ltd.

Contact Person: Tessa Huang

Tel: +8618933919125

Fax: 86-020-31143909-805

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products