Send Message
Home ProductsBattery Testing Equipment

IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH

IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH

  • IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH
IEC60068-2-1 40℃ ~ +150℃ Temperature Cycling Test Chamber Humidity Range 20% ~ 98%RH
Product Details:
Place of Origin: China
Brand Name: HongCe
Certification: Calibration certificate (cost additional)
Model Number: HB6215
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: plywood
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 10 sets per month
Contact Now
Detailed Product Description
Temperature Range: 40℃~+150℃ Temperature Fluctuation: ±0.5℃
Temperature Deviation: ≤±2.0℃ Temp. Overshoot: ≤±2℃
Humidity Fluctuation: ≤±2.5%RH Humidity Deviation: >75%RH:≤+2,-3%RH, <75%RH:≤±5%RH
High Light:

battery test chamber

,

battery discharge test equipment

IEC60068-2-1 Temperature Cycling Test Chamber

IEC60068-2-1 Temperature Cycling Test Chamber 40℃ ~ +150℃ For Testing Temperature Change Of Humidity Range 20% ~ 98%RH

 

Standard

The Temperature Cycling Test Chamber conform to the IEC60068-2-1:2007, IEC60068-2-2:2007, IEC60068-2-78:2007, IEC60068-2-30:2005, GJB150.3-1986, CJB150..4-1986, IEC62133-2012.

 

Application

This equipment mainly used for electric and electronic products,components and other materials high low temperature test,temperature change,damp heat etc. Environment simulate reliability test.

Other usage except this may cause personal injuries and machinery damages.

 

Limitation

a) Inflammable, explosive,easy volatile specimen test and storage.

b) Corrosive material and biologial specimen test and storage

c) Strong electromagnetic source specimen test and storage.

 

Parameter

 

 

Condition

Air cooling type under environment temp.+5℃~+35℃,relative humidity≤85%, No load(without specimen in the testing zone)
Temperature Range 40℃~+150℃
Temperature Fluctuation ±0.5℃
Temperature Deviation ≤±2.0℃
Temp. Uniformity ≤2.0℃
Temp. Heating Time From -40℃ to 80℃,full range non-linear average about5℃/mins,no load
Temp. Cooling Time From 80℃to -40℃ ,full range non-linear average about5℃/mins,no load
Temp. Overshoot ≤±2℃
Max. Loading No
Humidity Range 20%RH~98%RH
Humidity Fluctuation ≤±2.5%RH
Humidity Deviation >75%RH:≤+2,-3%RH, <75%RH:≤±5%RH
Constant Max.Heating Load No
Noise ≤70dB(A Level)
Effective Volume 150L
Inner Dimension W500 mm*H600 mm*D500 mm
Overall Dimension W700mm*H1750mm*D1570mm

 

 

 

 

Contact Details
Guangzhou HongCe Equipment Co., Ltd.

Contact Person: Tessa Huang

Tel: +8618933919125

Fax: 86-020-31143909-805

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products