IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel

IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel

  • IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel
  • IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel
  • IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel
  • IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel
IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel
Product Details:
Place of Origin: China
Brand Name: HongCe
Certification: Third party calibration certificate(cost additional)
Model Number: HC9915F
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: Plywood
Delivery Time: 35 days
Payment Terms: L/C, T/T
Supply Ability: 10 sets per month
Contact Now
Detailed Product Description
Standard: UL1054, UL943 Accuracy: 0.5%
Counter: 1 ~ 999999 Times Can Be Preset Channel: 1
High Light:

socket tester

,

electrical plug tester

 

IEC60669 Clause 18.3 Halogen Filament Lamp Load Bank For switches Of Overload Test

 

Standard
UL1054,UL943, IEC 60669-1 :2017 Clause 18.3

Application


it is suitable for the overload test with filament lamps for switches, supply 1.2 times rated current of test switches.

Technical parameters:

1. Input power: AC 220V, 20A, 50/60Hz (It depends on 
customer's national requirements)

2. the output voltage: AC 0 ~ 250V continuously adjustable,4 display instrument display, accuracy 0.5%

3. Test current: This is achieved by connecting the number of halogen lamps rated at 200W in parallel. (Number of halogen lamps: 30, switch rated current 16A); 
Output current:0~24 A(can be customed)

4. The system can automatically detect whether the halogen lamp is damaged. Once it is damaged, it can automatically access the spare lamp. When the number of normal lamps is not enough, the system will automatically stop the test and give an audible and visual alarm;

5. Touch screen display: test voltage, test current, number of tests, bulb failure location, warning light information.

6.Counter: 1 ~ 999999 times can be preset

7.the number of output channels: 1

8.overtime protection: with the test current continuous power circuit protection function for 5 seconds.

9. surge current coefficient: Meet the requirements of UL1054 5.7.9, about 10-18 times.

10. The control plane size: about 1200 × 800 × 1700 (mm)
 
 
 
Standard UL1054,UL943, IEC 60669-1 :2017 Clause 18.3
Output voltage 0~250V
Output current 0~24A
Accuracy 0.50%
Counter 1 ~ 999999 times can be preset
The control plane size 1200 × 800 × 1700 (mm)
Number of halogen lamps 30
switch rated current 16A
Control PLC, Programmable
Operation interface 7" Touch screen


Picture for reference:
 
 
IEC60669 Clause18.3 Overload Test with Filament Lamps Halogen Lamp Load Bank 24A PLC 1 Channel 0
 